Maintenance-free with no moving parts, ultrasonic technology allows the flow meter to measure with high precision and independent of the conductivity. The flow meter has the option to include pressure and temperature sensors. The device can be integrated into sensor networks via JUMO digiLine or IO-Link interface. Configuration is simple and via Bluetooth and app.
Datasheet – PDF
General technical data |
Measuring principle |
Ultrasonic (delay difference) |
Accuracy |
1 % of the measured value |
Measuring dynamics |
Up to 1:100 (0.1 to 10 m/s) |
Medium temperature |
Up to 80 °C (up to 95 °C with lower accuracy) |
Nominal pressure |
PN 16 |
Ambient temperature |
60 °C |
Outputs |
IO-Link (configurable: Pulse output (up to 10 kHz), Analog output, Binary input/output |
Display |
TFT display for easy operation and measured value display |
Process connection |
Pipe made of high-performance plastic with nominal widths from DN 15 to DN 32, G-type external thread with integrated seal |
Materials in contact with the medium |
PPSU, PEEK, EPDM (FKM) |
Protection type |
IP65/IP67 |
Housing |
Metal-free plastic housing |
Electrical connection |
M12 connector |
Additional measurands (optional) |
Temperature, pressure |
Special features |
Configuration via Bluetooth and app as well as RS485 and software (Digital Sensor Management); measurement of up to 3 measurands at 1 measuring point |
|
|
|
|
|
|
|
|
|
|
|
|