Flow Indicator – Flap and Spout Type
This new double window Flow Indicator range from Flow-Mon is most useful where visual inspection of the pipeline content is needed as a plant safety or product quality measure. The sizeable windows allow an excellent view of the conditions in the line.
The plain Spout design affords visual inspection only while the hinged internal Flap with its graduated scale allows a check on flow rate changes and for instance, affords repeatability of valve positioning. The Flap or Spout can be used in transparent or
slightly opaque solutions and gas services. Both units will operate in horizontal or vertical orientation (up only for Flap style)
Materials of Construction;
- Body & Covers – Stainless Steel 316: ASTM-A-351-2000 GR CF8M- Carbon Steel: ASTM-A-216-2000-GR-WCB- Bronze BS EN1982 CuSn5Zn5PB5-C-GS (formerly LG2)
- Glass – Toughened Borosilicate (DIN 7080) (16 bar) or Toughened Soda lime (BIS 3463) (40 bar)
- Gaskets – PTFE
- Flap – Stainless Steel 316
- Scale – Polycarbonate
- Fasteners – Stainless A2
- (Every effort will be made to meet any special connection and material requirements)
- Temperature – up to 250˚C