SPP-94 flow indicators giving instantaneous flow and totalised flow. SPP-94 is designed to work in tandem with the pulse flow transducers with current input of 0-20 mA or 4-20 mA. Wide range of total flow (up to 16 significant digits) enables flow volume control for a long time. Build in a batcher function makes possible application of SPP-94 in a wide range of industry branches (food production, pharmacy, paint and varnish). The REL / OC control outputs can adjust the level of measured signal and are controlled according to one or two threshold values. Moreover, the meter can be equipped with analogue outputs, according to the customer selection: active current output, passive isolated current output or active voltage output. The meter can be configured with the local keyboard or free S-Config software via the RS-485 communication port.
Inputs | measurement: current 0-20 mA or 4-20 mA, overload-protected,sinking current limited to about 40 mA; programmable: binary 24V DC, not separated |
---|---|
Power supply | 19V ÷ 50V DC; 16V ÷ 35V AC or 85 ÷ 260V AC/DC |
Power consumption | for 85 ÷ 260V AC/DC and 16V ÷ 35V AC power supply: max. 4,5 VA; 19V ÷ 50V DC power supply: max. 4,5 W |
Protection class | IP 65 (front), available additional frame IP 65 for panel cut-out sealing; IP 20 (case and connection clips) |
Operating temperature | 0°C ÷ +50°C (standard), -20°C ÷ +50°C (option) |
Display | LED, red, 6 x 13 mm high |
Measurement range | 0 ÷ 999999 + decimal point |
Accuracy | current measurement: 0.1% @25°C (for 0÷20 mA range) |
Analogue outputs | (available with 2 x REL or OC, see ordering): active current: operating range 0/4-20 mA (max. 0-24 mA), load resistance 700 Ω max., resolution 13 bit passive current: isolated, operating range 4-20 mA (max. 2,8-24 mA), load resistance 600 Ω@24VDC, resolution 13 bit; active voltage: operating range 0/1-5V, 0/2-10V (max. 0-11V), load resistance min. 2000 Ω, resolution 13 bit |
Total flow capacity | over 4 x 10^9 m3 with max. resistance 0,001 l |
Instantaneous flow unit | l or m3 per second, minute or hour |
Total flow unit | I or m3 |
Data memory | non-volatile memory, EEPROM type |
Communication interface | RS-485 / Modbus RTU (not galvanically isolated) |
Output | 2 or 4 relay 1A/250V AC (cos fi=1) or OC 30mA/30VDC/100mW; power supply output: 24V DC + 5% -10% / max 100 m |
Transmission parameters | 1200 ÷ 115200 bit/s, 8N1 and 8N2 |
Storage temperature | -10°C ÷ +70°C or -20°C ÷ +70°C (depending on version) |
Case dimensions | 96 x 48 x 100 mm |
Case | panel mounting |
Panel cut-out dimensions | 90,5 x 43 mm |
Instantaneous flow precision | selected from range: 0 ÷ 0.00000 |
Total flow precision | selected from range: 0 ÷ 0.000 |
Installation depth | min 102 mm |